Welcome to CW Green Tech Limited
info@cwlyautomation.com 86-136 6712 1125
Home      Products MTL5582B MTL Intrinsically Safe Isolator 5500 Series RTD-RTD Isolator
MTL5582B  MTL Intrinsically Safe Isolator 5500 Series RTD-RTD Isolator

MTL5582B MTL Intrinsically Safe Isolator 5500 Series RTD-RTD Isolator

  • Product Item : MTL5582B
  • Product Brand : MTL
  • INQUIRY

MTL5582B  MTL Intrinsically Safe Isolator 5500 Series RTD-RTD Isolator


MTL 5500 Intrinsically Safe Isolators Resistance Isolator MTL5582B


MTL4582B - MTL5582B RESISTANCE ISOLATOR to repeat RTD signals

The MTLx582B connects to a 2-, 3-, or 4-wire resistance temperature device (RTD) or other resistance located in a hazardous area, isolates it and repeats the resistance to a monitoring system in the safe area. The module is intended typically (but not exclusively) for use with Pt100 3-wire RTDs. Switches enable selection of 2-, 3-, or 4-wire RTD connection. The MTLx582B should be considered as an alternative, non-configurable MTLx575, for use in RTD applications where a resistance input is preferred or needed instead of 4/20mA. The design is notable for its ease of use and repeatability. The number of wires which can be connected on the safe-area side of the unit is independent of the number of wires which can be connected on the hazardous-area side. The module drives upscale in the case of open circuit detection.


MTL5582B product specification

SPECIFICATION

See also common specification

Number of channels

One

Location of RTD

Zone 0, IIC, T4 hazardous area

Div. 1, Group A, hazardous location

Resistance source

2-, 3-, or 4-wire* RTDs to BS 1904/DIN 43760 (100Ω at 0°C)

*user selectable by switches (factory set for 3-wire)

Resistance range

10Ω to 400Ω

RTD excitation current

200μA nominal

Output configuration

2, 3 or 4 wires (independent of mode selected for hazardous area terminals)

Output range

10Ω to 400Ω (from a 100μA to 5mA source)

Temperature drift

±10mΩ/°C typical (0.01%/°C @ 100Ω)

Response time

To within 4% of final value within 1s

Safety drive on open-circuit sensor

Upscale to 420Ω nominal

Transfer accuracy@20°C

<0.15Ω at excitation current 1 - 5mA

<0.25Ω at excitation current 0.5 - 1mA

 

LED indicator

Green: power indication

Power requirements, Vs

33mA at 24V

35mA at 20V

28mA at 35V

Maximum power dissipation within unit

0.8W at 24V

1.0W at 35V

Safety description

Terminals 1 and 3

Uo = 1.2V Io = 4mA Po = 1.2mW Um = 253V rms or dc

Non-energy-storing apparatus ≤ 1.5V, ≤ 0.1A, ≤ 25mW; can

be connected without further certification into any IS loop with

an open circuit voltage < 5V.

Terminals 1, 3, 4 and 5

Uo = 6.51V Io = 10mA Po = 17mW

Other related product models for MTL5500 range as below for your reference.

MTL5501-SR 

MTL5510 / MTL5510B / MTL5511

MTL5513 / MTL5514

MTL5514D / MTL5516C

MTL5517

MTL5521

MTL5522

MTL5523 / MTL5523V 

MTL5523VL 

MTL5524 

MTL5525

MTL5526 

MTL5531 

MTL5532

MTL5541

MTL5541A / MTL5541AS

MTL5544 / MTL5544S

MTL5544A / MTL5544AS

MTL5544 / MTL5544D / MTL5544S

MTL5546 / MTL5546Y / MTL5549

MTL5549Y / MTL5561

MTL5553 

MTL5573

MTL5575

MTL5576

MTL5582

MTL5582B

MTL5523V, MTL5523VL, MTL5546Y and MTL5553.

MTL5501-SR 

MTL5510 / MTL5510B

MTL5511 / MTL5513

MTL5514 / MTL5514D

MTL5516C / MTL5517

MTL5521

MTL5522 

MTL5523 / MTL5523V 

MTL5523VL 

MTL5524

MTL5525 

MTL5526 

MTL5531

MTL5532

MTL5533 

MTL5541 / MTL5541S

MTL5544 / MTL5544D

MTL5544S

MTL5541A / MTL5541AS

MTL5544A / MTL5544AS

MTL5546 / MTL5546Y

MTL5549 / MTL5549Y

MTL5561

MTL5553

MTL5573

MTL5575

MTL5576

MTL5581 

MTL5582

MTL5582B

 

MTL5018AC

MTL5501-SR

MTL5510

MTL5510B

MTL5511

MTL5513 

MTL5514

MTL5514D

MTL5516C

MTL5517

MTL5521

MTL5522

MTL5523

MTL5523V – V

MTL5524

MTL5525

MTL5526

MTL5541

MTL5541A

MTL5541AS 

MTL5541S

MTL5544

MTL5544A

MTL5544AS

MTL5544D

MTL5544S

MTL5546

MTL5546Y

MTL5549

MTL5549Y

MTL5573

MTL5575

MTL5576-RTD

MTL5576-THC

MTL5581

MTL5582

MTL5582B

MTL5991 

MTL5531

MTL5532

MTL5533

MTL5561

MPA5500

MTL5051

MTL5053

MTL5314

MTL5599